ARDMS SPI study guide
ARDMS SPI, administered by ARDMS, is mapped here as 5 topic areas; the heaviest are Apply Doppler Concepts (34%), Optimize Sonographic Images (26%) and Perform Ultrasound Examinations (23%).
About this course: Practice ultrasound physics, Doppler, image optimization, transducers and safety with audio teaching and recall cards.
ARDMS SPI at a glance
- Questions
- 110
- Time allowed
- 2 hours
- Passing standard
- 555 scaled (scale 300–700; FIXED scaled cut, not a raw %)
- Format
- multiple choice (~100 scored + ~10 unscored pilot)
- Standard / edition
- 2023 task-based Content Outline
- Administered by
- ARDMS
Source: 2023 task-based Content Outline, ARDMS. Confirm current details with the exam owner before you book.
Topic areas and weights
| Topic area | Weight | Concepts | Guide |
|---|---|---|---|
| Apply Doppler Concepts | 34% | 6 | Topic page |
| Optimize Sonographic Images | 26% | 1 | Section below |
| Perform Ultrasound Examinations | 23% | 2 | Section below |
| Provide Clinical Safety & QA | 10% | 1 | Section below |
| Manage Ultrasound Transducers | 7% | 4 | Section below |
Topic guides at a glance
Apply Doppler Concepts
34% of the course blueprint, 6 concepts. Emphasized: Doppler shift equation: delta-f=/c, Angle/cosine effect: 0 degrees=max Doppler shift; 90 degrees=zero shift; keep beam-to-flow angle ≤60° for vascular work and Nyquist limit = PRF/2 — maximum unambiguous PW Doppler shift; worked: PRF=8 kHz → Nyquist=4 kHz. Watch for: Aliasing fixed by lowering PRF/scale — WRONG, raise it.
Study plan in this course
- Apply Doppler Concepts — 12 cards · free
- Optimize Sonographic Images — 11 cards · full course
- Perform Ultrasound Examinations — 9 cards · full course
- Provide Clinical Safety and QA — 6 cards · full course
- Manage Ultrasound Transducers — 6 cards · full course
Optimize Sonographic Images
Optimize Sonographic Images carries 26% of the ARDMS SPI blueprint used in this course, the second-largest of its 5 weighted areas. It spans 1 concept. The course teaches it in 1 study unit: Optimize Sonographic Images.
What Optimize Sonographic Images covers
- Axial resolution = SPL/2; improves with higher frequency and shorter pulses; always better than lateral resolution — 02-blueprint.md §d2.01
Common mistakes in Optimize Sonographic Images
- Swapping axial (along beam, SPL/2) and lateral (side-by-side, beam width) — the #1 Optimize confusable
- Thinking lateral resolution is better than axial — it is not
- Raising gain to fix deep-field darkness — use TGC instead
- Believing higher frequency improves penetration — it worsens it
- Confusing shadowing (attenuator) with enhancement (fluid) direction
- Thinking more focal zones is free — it costs frame rate
Key terms for Optimize Sonographic Images
Axial resolution · Lateral resolution · TGC (time-gain compensation) · Dynamic range · Artifacts
Official references for Optimize Sonographic Images
- 02-blueprint.md §d2.01
- 02-blueprint.md §d2.02
- 02-blueprint.md §d2.03
- 02-blueprint.md §d2.04
- 02-blueprint.md §d2.05
- 02-blueprint.md §d2.06
- 02-blueprint.md §d2.07
- 02-blueprint.md §d2.08
- 02-blueprint.md §d2.09
- 02-blueprint.md §d2.10
- 02-blueprint.md §d2.11
In the app this area comes with 11 memory cards and 29 module-quiz questions in the full course.
Perform Ultrasound Examinations
Perform Ultrasound Examinations carries 23% of the ARDMS SPI blueprint used in this course, the third-largest of its 5 weighted areas. It spans 2 concepts. The course teaches it in 1 study unit: Perform Ultrasound Examinations.
What Perform Ultrasound Examinations covers
- Pulse-echo principle: distance = / 2, with c = 1540 m/s assumed; 13 µs of round-trip time ≈ 1 cm of depth — 02-blueprint.md §d3.01
- Knobology: output power; gain/TGC; depth; focus; frequency; power affects patient exposure, gain does not — 02-blueprint.md §d3.09
Common mistakes in Perform Ultrasound Examinations
- Propagation speed is constant/operator-settable — WRONG, set by the MEDIUM; machine only assumes 1540
- Impedance vs attenuation confused — reflection-at-boundary vs loss-along-path
- Intensity vs power confused — W/cm² vs W
- Thinking frequency changes propagation speed — it does not
- Forgetting the ÷2 in the range equation (round-trip)
Key terms for Perform Ultrasound Examinations
Propagation speed (c) · Frequency (f) / period (T) · Wavelength (λ) · Acoustic impedance (Z) · Intensity reflection coefficient (IRC) · Attenuation · Decibel (dB) · Power vs intensity
Official references for Perform Ultrasound Examinations
- 02-blueprint.md §d3.01
- 02-blueprint.md §d3.02
- 02-blueprint.md §d3.03
- 02-blueprint.md §d3.04
- 02-blueprint.md §d3.05
- 02-blueprint.md §d3.06
- 02-blueprint.md §d3.07
- 02-blueprint.md §d3.08
- 02-blueprint.md §d3.09
In the app this area comes with 9 memory cards and 25 module-quiz questions in the full course.
Provide Clinical Safety & QA
Provide Clinical Safety & QA carries 10% of the ARDMS SPI blueprint used in this course, the 4th-largest of its 5 weighted areas. It spans 1 concept. The course teaches it in 1 study unit: Provide Clinical Safety and QA.
What Provide Clinical Safety & QA covers
- Two bioeffect mechanisms: thermal and mechanical/non-thermal; cavitation is NOT thermal — 02-blueprint.md §d4.01
Common mistakes in Provide Clinical Safety & QA
- TI vs MI swapped — TI = heat/thermal; MI = cavitation/mechanical
- Intensity vs power confused (W/cm² vs W) — resurfaces in safety context
- Thinking higher gain raises patient exposure — only output power does
- Cavitation classified as thermal — it is mechanical/non-thermal
Key terms for Provide Clinical Safety & QA
TI / MI · ALARA · SPTA
Official references for Provide Clinical Safety & QA
- 02-blueprint.md §d4.01
- 02-blueprint.md §d4.02
- 02-blueprint.md §d4.03
- 02-blueprint.md §d4.04
- 02-blueprint.md §d4.05
- 02-blueprint.md §d4.06
In the app this area comes with 6 memory cards and 11 module-quiz questions in the full course.
Manage Ultrasound Transducers
Manage Ultrasound Transducers carries 7% of the ARDMS SPI blueprint used in this course, the 5th-largest of its 5 weighted areas. It spans 4 concepts. The course teaches it in 1 study unit: Manage Ultrasound Transducers.
What Manage Ultrasound Transducers covers
- PZT active element: piezoelectric effect converts electricity to sound and sound to electricity — 02-blueprint.md §d5.01
- Q-factor = operating frequency / bandwidth; imaging probes are LOW-Q; CW Doppler probes are HIGH-Q — 02-blueprint.md §d5.04
- Transducer types: Linear array; Curvilinear/convex array; Phased array — 02-blueprint.md §d5.05
- Probe care: no autoclave; inspect for cracks; reprocess per contact level; avoid dropping/mechanical stress — 02-blueprint.md §d5.06
Common mistakes in Manage Ultrasound Transducers
- Thinking a thicker backing/damping layer worsens axial resolution — it IMPROVES it
- Confusing matching layer (impedance bridge to body) with backing/damping layer (shortens pulse)
- Believing high-Q is best for imaging — low-Q is (wider bandwidth)
- Thinking probes can be autoclaved — they cannot (Curie point)
Key terms for Manage Ultrasound Transducers
PZT · Curie point · Q-factor
How Manage Ultrasound Transducers connects to other areas
- Q-factor = operating frequency / bandwidth; imaging probes are LOW-Q; CW Doppler probes are HIGH-Q links to PW vs CW Doppler: PW=range-resolved but aliasing-limited; CW=no aliasing/unlimited velocity but no range resolution — Apply Doppler Concepts
Official references for Manage Ultrasound Transducers
- 02-blueprint.md §d5.01
- 02-blueprint.md §d5.02
- 02-blueprint.md §d5.03
- 02-blueprint.md §d5.04
- 02-blueprint.md §d5.05
- 02-blueprint.md §d5.06
In the app this area comes with 6 memory cards and 8 module-quiz questions in the full course.
Official references
- 02-blueprint.md §d4.03
- 02-blueprint.md §d4.06
- 02-blueprint.md §d5.06
- 02-blueprint.md §d1.01
- 02-blueprint.md §d1.02
- 02-blueprint.md §d1.03
- 02-blueprint.md §d1.04
- 02-blueprint.md §d1.05
- 02-blueprint.md §d1.06
- 02-blueprint.md §d1.07
- 02-blueprint.md §d1.08
- 02-blueprint.md §d1.09
- 02-blueprint.md §d1.10
- 02-blueprint.md §d1.11
- 02-blueprint.md §d1.12
- 02-blueprint.md §d2.01